home bbs files messages ]

Just a sample of the Echomail archive

Cooperative anarchy at its finest, still active today. Darkrealms is the Zone 1 Hub.

   WX_TALK      Not sure about this one      1,256 messages   

[   << oldest   |   < older   |   list   |   newer >   |   newest >>   ]

   Message 377 of 1,256   
   mark lewis to Mark Hofmann   
   Sandy.   
   04 Nov 12 17:05:32   
   
   RW> That's normal too.  Did you wire that into your service   
   RW> panel?  If so, hope you wired in a transfer switch which   
   RW> isolates your house from the grid when it's running.   
      
    MH> I shut off the "Main" breaker that comes in from the street before   
    MH> doing anything.  It all worked fine and once I knew we had power in   
    MH> the neighborhood, I shut off the generator, unplugged the   
    MH> connections, and reset things on the panel.   
      
   we have a special plug and socket that is in place between our power feed and   
   our main breaker box... there's only one socket and two plugs... ya can't go   
   wrong and feed power back into the neighborhood ;)   
      
     ============================================================   
     on commercial power:   
                                            ---- generator power   
                                           /   
     house       breaker    socket       <-   
     wiring ---- panel ---- box   --<<--   
                                        \   
                                         ---- commercial power   
     ============================================================   
     on generator power:   
                                          ---- generator power   
                                         /   
     house       breaker    socket      /   
     wiring ---- panel ---- box   --<<--   
                                         <-   
                                           \   
                                            ---- commercial power   
     ============================================================   
      
   we also use only specific circuits in our house wiring when we are on the   
   generator... those circuits are specially marked and coded... namely the well   
   pump, the fridges/freezers, the AC/Heat, the computer network essentials (ie:   
   DSL modem, switches, no printers), a few lights and one or two TVs...   
   everything else is disconnected... we have GAS for the actual heat part of the   
   AC/Heat unit, the water heater and the stove... plus there's a GAS grill on   
   the deck...   
      
   the main problem is getting the generator started but we're working on a   
   pullcord replacement thing that has a 12Volt car battery and some sort of   
   starter that'll spin the generator until it fires... we just can't pull that   
   cord any more without falling over... then it is a matter of ensuring that the   
   25+ gallons of fuel are clean and ready for use that fuel gets cycled with our   
   mower so it is pretty fresh...   
      
   we get 8 to 12 hours on a tank of fuel in our generator and that greatly   
   depends on the load... we also have a method of filling the generator tank   
   while it is running so we don't have to shut it down and worry about trying to   
   get it started again... this is another mod like our big power socket mod   
   above... in this case, the tank is is removed from the generator and a longer   
   fuel line is afixed... one could also use a larger tank if they desired to do   
   so... with the tank separated from the generator, there's no danger of   
   spilling fuel on the running generator :)   
      
   )\/(ark   
      
    * Origin:  (1:3634/12)   

[   << oldest   |   < older   |   list   |   newer >   |   newest >>   ]