TZUTC: -0800   
   MSGID: 1050.wildcat!@1:103/705 2496b738   
   REPLY: 1:342/201 1ae1f046   
   PID: Synchronet 3.18c-Win32 master/bc5bfa5f6 Feb 20 2021 MSC 1928   
   TID: SBBSecho 3.13-Linux master/bc5bfa5f6 Feb 19 2021 GCC 8.3.0   
   BBSID: VERT   
   CHRS: ASCII 1   
    MJ> I currently do not understand how WC5 can receive a call from an external   
    MJ> mailer if there is no command on the WC5 side to receive a live   
    MJ> connection. In previous versions of Wildcat the "wildcat.exe" command   
    MJ> supported the "/B " switch to pass a live connection to the BBS.   
    MJ>    
    IJ> I just want to clarify WC5, the old version number and name for the   
    IJ> current WINServer... It is a windows 32bit program and needs to run   
    IJ> with other 32bit mailer programs.    
      
   I understand that my version of WC5 is a Windows 32-bit GUI application.   
   However my version is apparently not WINServer (as detailed in its connection   
   banner). (Notice from the following banners that one says WINServer and the   
   other does not).   
      
   My banner:   
      
   ==================================================   
   Wildcat! for Win95/NT (c) 1995,96 Mustang Software, Inc. All Rights Reserved.   
   Registration number: 00-0000. v5.00. Node: 1.   
   ==================================================   
      
   Wildcat 5.3:   
      
   ==================================================   
   Wildcat! Interactive Net Server (c) 1999 Santronics Software, Inc.   
   Registration number: 00-0000 v5.3.449 (Apr 26 2000) Node: 1   
   ==================================================   
       
    IJ> WC5 AKA Winserver readily answers a modem caller... Does not need a   
    IJ> mailer or any software... it has it built in. The program that starts   
    IJ> the BBS to accept any calls is called wcOnline.exe. Once that is    
    IJ> started, assuming you've configured things right, the BBS will accept   
    IJ> HTTP, FTP, Telnet & Modem period. For the most part this should look   
    IJ> and fee the same way for all versions... There has been changes since   
    IJ> 1990 (Whatever) when WC5 came out... but what I just wrote should be   
    IJ> what you should expect from WC5/WINServer...    
      
   Wildcat version 5.00 does not come with HTTP or FTP (these were add-on   
   products that needed to be purchased separately). I understand that wcOnline   
   handles connections between callers and wcServer. But unlike a lot of DOS   
   BBS's, WC5 does not have an option to load an active connection (high carrier)   
   into the BBS from the command line.   
      
    IJ> NOW, the wildcat.exe sounds like the DOS version of wildcat. I have   
    IJ> been around since day 1 of WC5 project, I have the current version of   
    IJ> WINServer and run it, it is not the same as the as the DOS version.    
    IJ> If it is true that you have the DOS version... you can use any DOS   
    IJ> Mailer you want... Frontdoor, Intermail, Binkley... Bla Bla Bla. What   
    IJ> you need is the command line for your batch file to pull up the BBS   
    IJ> after the mailer passes the user the BBS. This is a different   
    IJ> question and it probably can be answered here... If you want me to   
    IJ> answer the question I'll have to download the DOS version and read the   
    IJ> docs... I can and will if I have to....    
      
   I have both DOS and Windows versions (WC4 and WC5).   
      
   If an external mailer like Frontdoor can exit without dropping carrier, and   
   then SexPOTS can pickup and resume carrier and forward the connection on to   
   WC5, then SexPOTS sounds like it might work.   
      
    IJ> NOW, I'm sorry if you own the current version of Wildcat... the   
    IJ> windows 32bit version... it runs differently... wcOnline.exe and my   
    IJ> mailer pxOnline.exe (Platinum Express) run at the same time... in   
    IJ> different windows and a human caller is passed directly to the BBS   
    IJ> without any SysOp intervention... seamless easy as pi.    
    IJ> So, is there a way to pass a human caller, I'm a summing it's a dial   
    IJ> up line with a physical modem... The Windows version... YES... Use any   
    IJ> windows mailer, Binkley has one... AND use a program called   
    IJ> SexPOTS.exe and you can have people dial in via modem and it'll be   
    IJ> passed to your BBS via telnet. This is the simplest, easiest and it's   
    IJ> free.    
      
   Does SexPOTS work with virtual modems (eg. an inbound call via TCP/IP) ?   
      
   IJ> Now, as I said, I have been around since day 1 of WC5, not WC4, I have   
    IJ> seen a few things. I have talked about BGFax running as a frontend to   
    IJ> WC5... I used it and it worked fine. It's been 25 years and I don't   
    IJ> recall how it did it but all I know was that it was easy. Moreover, I   
    IJ> was on the beta team for InterMail and they were working on a mailer   
    IJ> that compatible with WC5 but it never made it into production... The   
    IJ> author, Peter, went MIA...    
      
   Is InterMail a Frontdoor clone ? (it looks like a lot like Frontdoor).   
       
    IJ> Anyway... to be honest with you... if you have WC5/WINServer just   
    IJ> spend the money and get its partner Platinum Express... it sells for a   
    IJ> 100 bucks and it might be the best 100 you spent... Hand in glove   
    IJ> works perfect... BUT even if you had those 2 programs you might need   
    IJ> an other... BinkP or Internet Rex.    
       
   Does Platinum Xpress support BinkP ?   
       
    IJ> Apparently not.... and I wrote all that stuff.... SHIT... in my   
    IJ> Platinum Express directory is an exe called pxmail.exe that you can   
    IJ> run in a batch file and it'll toss and import your fidonet mail....   
    IJ> and I can only assume that it's looking at your PXW setup to know how   
    IJ> things are configured.    
      
   If "pxmail.exe" only works with Platinum Xpress then it is no good to me.   
      
   --- SBBSecho 3.13-Linux   
    * Origin: Vertrauen - [vert/cvs/bbs].synchro.net (1:103/705)   
   SEEN-BY: 1/123 19/10 90/1 103/705 105/81 120/340 123/131 124/5016   
   SEEN-BY: 203/0 218/700 221/0 1 6 242 360 226/30 227/114 702 229/424   
   SEEN-BY: 229/426 550 664 1016 1017 230/150 240/5832 249/206 317 280/464   
   SEEN-BY: 292/8125 317/3 320/219 322/757 342/200 396/45 423/81 633/0   
   SEEN-BY: 633/267 280 281 412 416 509 640/1138 1321 1384 712/620 848   
   SEEN-BY: 770/1   
   PATH: 103/705 280/464 221/1 640/1384 712/848 633/280 229/426   
      
|