Just a sample of the Echomail archive
Cooperative anarchy at its finest, still active today. Darkrealms is the Zone 1 Hub.
|    SYNC_SYSOPS    |    Synchronet Multinode BBS Software Suppor    |    33,243 messages    |
[   << oldest   |   < older   |   list   |   newer >   |   newest >>   ]
|    Message 32,184 of 33,243    |
|    Digital Man to Basis    |
|    TICKIT Configured TicFilePwd is empty    |
|    01 Jul 25 13:54:54    |
      TZUTC: -0700       MSGID: 58280.sync_sys@1:103/705 2cca64c6       REPLY: 58278.sync_sys@1:103/705 2cc9ec69       PID: Synchronet 3.21a-Linux master/2588c5cf7 Jun 12 2025 GCC 12.2.0       TID: SBBSecho 3.28-Linux master/a43ca30ea Jun 18 2025 GCC 12.2.0       COLS: 80       BBSID: VERT       CHRS: CP437 2       FORMAT: flowed       NOTE: FSEditor.js v1.105        Re: TICKIT Configured TicFilePwd is empty        By: Basis to All on Tue Jul 01 2025 07:58 am               > Hello,        > Been troubleshooting this one for a few days. I'm trying to get files        > processed with tickit from an FTN. The files get to my fido\inbound        > correctly. I have a password configured in echocfg for ticfilepwd, and        > confirmed it's there under the node in sbbsecho.ini.        >        > [node:21:4/100@fsxNet]        > Name = fsxNet        > Comment =        > Archive = ZIP        > PacketType = 2+        > PacketPwd =        > AreaFix = true        > AreaFixPwd = MYPW        > SessionPwd = MYPW        > TicFilePwd = MYPW        >        > What I'm seeing is:        >        > 7/1 07:48:02a TICKIT Parsing ../fido/inbound\0th2942p.tic        > 7/1 07:48:02a TICKIT Configured TicFilePwd is empty, but TIC file has a        > password, node: 21:4/100               > I have other FTN confiruations that seem to work ok using the same setup.        >        > I'm wondering where maybe to look as I'm out of ideas.              The problem (a frequent one with TickIT) is that "21:4/100" is not the same       address as "21:4/100@fsxnet". Either remove the domain from the linked node       configuration in echocfg or add it to the tickit cfg (if it supports 5D       addresses, I don't remember).       --         digital man (rob)              Sling Blade quote #1:       Karl: I've killed Doyle with a lawn mower blade. Yes, I'm right sure of it.       Norco, CA WX: 85.1øF, 39.0% humidity, 11 mph W wind, 0.00 inches rain/24hrs       --- SBBSecho 3.28-Linux        * Origin: Vertrauen - [vert/cvs/bbs].synchro.net (1:103/705)       SEEN-BY: 103/13 705 105/81 106/201 124/5016 128/187 129/14 153/757       SEEN-BY: 153/7715 154/10 30 110 203/0 218/700 221/0 226/30 227/114       SEEN-BY: 229/110 206 317 400 426 428 550 700 705 240/1120 5832 263/1       SEEN-BY: 266/512 280/464 5003 5006 291/111 292/8125 301/1 320/219       SEEN-BY: 322/757 341/66 234 342/200 396/45 423/120 460/58 256 1124       SEEN-BY: 467/888 633/280 712/848 770/1 902/26 5020/400 8912 5054/30       SEEN-BY: 5075/35       PATH: 103/705 280/464 460/58 229/426           |
[   << oldest   |   < older   |   list   |   newer >   |   newest >>   ]
(c) 1994, bbs@darkrealms.ca