   Hello Mike!   
      
   Wednesday March 13 2024 18:47, you wrote to me:   
      
    > On 13/03/2024 03:32, Vincent Coen wrote:   
    >> systems I use APC smart UPS's connect to a large adaptor block that   
    >> hold around 9 sockets with the APC unit being 1000Va. I did have a   
    >> 2k2 VA but the   
      
    > And what's the standby current of such a UPS?   
      
   Standby ?   
      
   Assuming it is fully charged which would be normal (assuming no outage in the   
   preceding 2 - 3 hours 95% or better.   
      
   Otherwise do you mean the estimated run time if so then system under power in   
   watts per   
   hour under the rated size - 25% so lets say :   
      
   750 w   
   ---- = 150 = long time :)   
   5 w   
      
      
   Also e.g., my desktop / server system with an estimated consumption of 250w   
   (and it is lower as using modular PSU, 85% eff or better ) would be around 3   
   hours but that assumes there is nothing else under load and there is such as::   
   Router   
   Baby Hub   
   Monitor ( but only when I am using it )   
   Telephone systems including VOIP adaptor   
   Residual loading - not known as no means to test it.   
      
   Total time with a 25% battery remaining around 90 minutes allowing for 7   
   minutes to shut down and battery remaining of around 22-23 % approx.   
      
   If I am present when power goes I can shutdown the monitor and let it does its   
   thing if battery drops to predetermined amount of 25%.   
   That said during the cold months (UK wise) and I am around I will manually   
   shutdown after 15 minutes and transfer the UPS o/p to the C.H. and turn it on   
   in which case over 24 hours runtime, but so far has never got any where near    
   it   
   before power is restored. My old house in a village power outs could be longer   
   and hence the reason for 2 x 2.2Kva UPS's. ( Also smart models ).   
      
   Gave me enough time to power up my ex-mil generator if needed but it was a   
   petrol model so did go through it - petrol I mean so had to keep a few jerry   
   cans filled with fresh fuel as a JIC.   
      
      
   Vincent   
      
   --- Mageia Linux v8 X64/Mbse v1.0.8.5/GoldED+/LNX 1.1.5-b20180707   
    * Origin: Air Applewood, The Linux Gateway to the UK & Eire (2:250/1)   
   SEEN-BY: 1/120 10/0 1 15/0 18/0 25/0 21 50/109 90/1 103/705 105/81   
   SEEN-BY: 106/201 123/0 25 126 180 200 755 3001 128/260 129/305 135/115   
   SEEN-BY: 135/225 153/7715 218/0 1 601 700 870 930 221/1 6 222/2 226/30   
   SEEN-BY: 227/114 229/110 111 112 113 200 206 307 317 400 426 428 470   
   SEEN-BY: 229/550 616 664 700 240/1120 250/0 1 3 4 5 6 7 8 10 11 13   
   SEEN-BY: 250/14 15 263/0 5 266/512 275/1000 282/1038 291/111 292/854   
   SEEN-BY: 299/6 301/1 113 812 320/219 322/757 335/364 342/200 396/45   
   SEEN-BY: 460/58 463/68 467/4 888 633/280 712/848 1321 2320/105 3634/0   
   SEEN-BY: 3634/12 56 57 119 5001/100 5005/49 5020/400 1042 4441 5030/49   
   SEEN-BY: 5054/8 5061/133 5075/35 128 5090/958   
   PATH: 250/1 3634/12 5020/1042 301/1 218/700 229/426   
      
|