Just a sample of the Echomail archive
Cooperative anarchy at its finest, still active today. Darkrealms is the Zone 1 Hub.
|    RAILFAN    |    Trains, model railroading hobby    |    3,261 messages    |
[   << oldest   |   < older   |   list   |   newer >   |   newest >>   ]
|    Message 1,965 of 3,261    |
|    Stephen Sprunk to hancock4@bbs.cpcn.com    |
|    Re: Home signal--flashing green over red    |
|    21 Dec 15 15:26:04    |
      From: stephen@sprunk.org              On 21-Dec-15 12:23, hancock4@bbs.cpcn.com wrote:       > Would anyone know the specific indication of the following signal:       >       > At an interlocking, a flashing green light over a red light.              That's Limited Clear on a dwarf signal; on a regular signal, it would be       red over flashing green. NORAC has no flashing green over red aspect on       a regular signal.              Note that, in all cases, an undetected failure of the signal to flash       properly results in a safe (but slower) indication, e.g. from Limited       Clear to Medium Clear or Advance Approach to Approach.              S              --       Stephen Sprunk "God does not play dice." --Albert Einstein       CCIE #3723 "God is an inveterate gambler, and He throws the       K5SSS dice at every possible opportunity." --Stephen Hawking              --- SoupGate/W32 v1.03        * Origin: LiveWire BBS -=*=- UseNet FTN Gateway (1:2320/1)    |
[   << oldest   |   < older   |   list   |   newer >   |   newest >>   ]