|    Andrew Leary to Robert Wolfe    |
|    FD/2 and Max/2    |
|    07 Sep 17 21:20:12    |
      Hello Robert!              07 Sep 17 00:02, you wrote to all:               RW> + 06 Sep 23:51:53 MAX Begin, v3.01 (task=1)        RW> ! 06 Sep 23:51:53 MAX SYS0032: Cannot open com port (com1)        RW> ! 06 Sep 23:51:53 MAX Communications driver not properly installed               RW> However, whenever I run Maximus/2 in WFC mode, I do not get the above        RW> error message.              Do you have the port-sharing parameter added to your SIO command line in        CONFIG.SYS?              ie:              DEVICE=C:\SIO\SIO.SYS (COM1,3F8,IRQ4,-) (COM2,2F3,IRQ3,-)        (COM3,INTERNET:3E8,NONE:IRQ4,-) (COM4,INTERNET:2E8,NONE:IRQ3,-)              This is for a standard COM1 and COM2, and virtual COM3 and COM4. The dash (-)        parameter enables sharing the port between applications.              Andrew              --- GoldED+/LNX 1.1.5-b20170303        * Origin: Phoenix BBS * phoenix.bnbbbs.net (1:320/219)    |