Ref: 99970044
Title: Release Note - SW/200-A/BSC/SDLC Ver 22020 (Pt No 86-0172-00 rev 02)
Date: 10/20/89

Copyright 3Com Corporation, 1991.  All rights reserved.

Software Release
SW/200-A/BSC/SDLC Version 22020
October 20, 1989
Part Number: 86-0172-00
               Revision: 02

TO:  CS/210 Users
FROM: 3Com Corporation
SUBJECT: SW/200-A/BSC/SDLC Version 22020
DATE: October 20, 1989

Enclosed is a distribution diskette containing SW/200-A/BSC/SDLC Version 22020
(Part Number: 83-0073-05) for use with a CS/210 that supports a 3 1/2-inch
floppy disk drive.

This release memo describes the compatibility, copy procedure, and limitations
of this software.


Compatibility

SW/200-A/BSC/SDLC Version 22020 operates with the following 3Com products and
software releases:

 CS/1 running SW/1-A/BSC/SDLC Version 20060 or later
 IB/3 running SW/20-IB Version 11000 or later
 NCS/150 running SW/150-NCS Version 10010 or later
 NCS/AT running SW/AT-NCS Version 11000 or later

Table 1 illustrates the hardware and firmware compatibility requirements of
SW/200-A/BSC/SDLC Version 22020.


Table 1  Hardware/Firmware Compatibility


 Product   Software                             Firmware

 CS/210    SW/200-A/BSC/SDLC Version 22020      F2 MMON 01A
           or later



** NOTE **

 You must press the Return key after you type each command in all procedures
described in this release memo.




Copying the Software

Before you run SW/200-A/BSC/SDLC Version 22020 on your CS/210, make a copy of
the distribution diskette using the following procedure:

1. Attach a terminal to port 0 of the server.

2.   Make sure that there is no diskette in the disk drive.  Then power on
the server.   The Self Test LED turns on.

3. Reset the server, and press the hardware interrupt switch.  For further
information  on the location and operation of the hardware interrupt
switch, refer to "Hardware  Interrupt Switch" in the Series/200
Installation Guide.

4. Press the Return key.  The monitor prompt (>) appears.

5. Perform firmware configuration on the server if necessary.  Otherwise, go
   on to  the next step.

Refer to "Firmware Configuration" in the Series/200 Installation Guide for
further  information on firmware configuration.  After you perform firmware
configuration,  return to the monitor prompt (>).

6. At the monitor prompt (>), type the following command to make a copy of the
   distribution diskette:

         co <n>

  where n is the number of copies to be made.  The following message appears
  on the  screen:

         insert master and hit the Return key

7. Insert the SW/200-A/BSC/SDLC Version 22020 distribution diskette in the
   disk  drive.  Then press the Return key.

  The following messages appear on the screen if the read completes
  successfully:

         reading ... OK
         insert copy 1 and hit the Return key

 In the actual display, the number in the message may vary according to the
number  of copies you have made.  If the message "read error" appears instead
of the  message "OK," contact an authorized 3Com service representative for
help.

8. Remove the SW/200-A/BSC/SDLC Version 22020 distribution diskette from the
   disk drive, and store it in a safe place.  Insert a blank, 135 TPI,
   double-sided,  double-density, 3 1/2 inch diskette in the disk drive.  Then
   press the Return key.



   If the copy completes successfully, the following messages appear on the
   screen:

         formatting ... writing ... verifying ... OK
         copy completed

9. Remove the diskette from the disk drive, and label it "SW/200-A/BSC/SDLC
   Version 22020."

10. Before you upgrade from SW/200-A/BSC/SDLC Version 22010 to Version 22020,
    copy the global, macro, and configuration files saved on your Version
    22010 diskette by inserting the Version 22010 diskette and typing the
    following command:

         r 4e1 103000 15E00

11. Insert the newly made working copy of SW/200-A/BSC/SDLC Version 22020 and
    type the following command:

         w 4e1 103000 15E00

 The global, macro, and configuration files are now stored on your working
 copy of  SW/200-A/BSC/SDLC Version 22020.  You can now use this copy on your
 server.

** NOTE **

 If you use the configurations, macros, and global files copied from a
 previous  version of SW/200-A/BSC/SDLC, you must use the SETD command to set
 the  value of the AUditTrailType, TimeZone, DaylightSavingsTime,
 NetMapBroadcast,  and MacType parameters after booting the server.


Sysgen

System generation can be performed on the CS/210 running SW/200-A/BSC/SDLC Ver
sion 22020.  The Sysgen parameters and default values for the CS/210 are the
same as for the CS/200.  Refer to the sections on the CS/200 in the
Configuration Guide for further information on the Sysgen program.

To start the Sysgen program, follow these steps:

1. Attach a terminal to port 0 on the CS/210.

2. Make sure that there is no diskette in the disk drive of the CS/210, and
   then power  on the CS/210.  The Self Test LED turns on.

3. Reset the CS/210 and press the hardware interrupt switch.  For further
   information  on the location and operation of the hardware interrupt
   switch, refer to "Hardware  Interrupt Switch" in the Series/200
   Installation Guide.

4. Press the Return key.  Then the monitor prompt (>) appears.




5. Perform firmware configuration if necessary.  Otherwise, go on to the next
   step.

 Refer to "Firmware Configuration" in the Series/200 Installation Guide for
further  information on firmware configuration.  After you perform firmware
configuration,  return to the monitor prompt (>).

6. Insert into the disk drive the SW/200-A/BSC/SDLC Version 22020 diskette
   that  you created in the software copy procedure.

7. At the Monitor prompt (>), type the following command to invoke the Sysgen
   program:

         bt 1d

 The Sysgen program is invoked, and the Main Menu is displayed.  Refer to
the  Configuration Guide for further information on the Sysgen program.


Limitations

SW/200-A/BSC/SDLC Version 22020 has the following limitation:

 Only three echo requests may be outstanding at any given time.  If more
than three  users simultaneously enter the PIng command, the following message
appears:

         Can't Ping now - try later


Documentation

The following manuals are shipped with SW/200-A/BSC/SDLC Version 22020:

 XNS Connection Service User's Guide (11/89)
 (Part Number: 09-0174-00)

 Network Management Guide (9/87)
 (Part Number: 09-0067-02)

 Getting Started Guide (2/87)
 (Part Number: 09-0043-01)

 Configuration Guide (2/88)
 (Part Number: 09-0093-01)

 XNS Connection Service Quick Reference Guide
 (Part Number: 09-0062-00)

For more information on network planning, refer to the following:

 Series/200 Installation Guide (6/88)
 (Part Number: 09-0151-00)

 LAN Planning Guide (2/88)
 (Part Number: 09-0085-01)