Ref: 23230016
Title: WD EtherCard Plus May Cause Problems with 3+Start Server
date: 7/29/91

Copyright 3Com Corporation, 1991.  All rights reserved.


Recently, a customer used a Western Digital EtherCard Plus network adapter
in a 3+ 1.6 PC server running 3+Start and 3+Share.  3Stations would begin to
load device drivers in the normal order, that is:  3STATION.SYS, PRO.SYS,
BUF.SYS, ETH100.SYS etc.  But at about SPP.SYS, a message would appear
"Error Reading Drive C:", and bootup would stop.  All other 3+ functions to
the server worked fine.  PC workstations could link to the server and run
applications, but 3+ Start would not work correctly.

Replacing the Western Digital EtherCard Plus with a 3Com EtherLink II (3C503)
adapter solved the problem.  The problem may have been caused by a limitation
of the Start service in conjunction with the WE EtherCard Plus.  The device
driver for the WD EtherCard Plus was not submitted to 3Com for certification
or testing in 3+ PC Servers.  Therefore, for best results, always use 3Com
adapters in PC servers running either 3+ or 3+Open Start Service.