Ref: 22140003
Title: Report Table Poblems with Paradox 3.5
Date: 03/18/91

Copyright 3Com Corporation, 1991.  All rights reserved.

Problems have been noted when using Borland's Paradox 3.5 to create and
edit report forms on a networked drive.

The problem usually surfaces after the user has saved a report form on
the net drive and attempts to edit it through the Paradox report editor.
The returned error code is R106.

According to Borland technical support, the workaround is to start Paradox
with the -REAL option, forcing Paradox to start in real mode instead of the
default protected mode.  The syntax of this command is

        C:\> PARADOX -REAL  (non-caps sensitive)

Also, the report form must be deleted and recreated, since it was corrupted
from the previous session.

This is a Paradox problem and has been reported to Borland.  A fix will
be included in the next release of Paradox.