Ref: 19140003
Title: NET808 on a DOS Enhanced netstation
date: 1/31/90

Copyright 3Com Corporation, 1991.  All rights reserved.

3Com testing of the DOS Enhanced netstation has revealed a problem
that occurs infrequently after running a copy and compare test from a
network drive for several hours.  The test fails with the message:

NET808: Incorrect Response from Network

The problem is caused by Write&Unlock behind and Write&Close behind
optimizations included in the DOS Enhanced redirector (NETWKSTA) code.

To work around the problem, edit the DOS Enhanced netstation's LANMAN.INI
file, changing the value of OPTIMIZATIONS= from the current value of 3 to
the Microsoft default value of 1.  The Write&Unlock behind and
Write&Close behind optimizations will be disabled.