Ref: 18960019
Title: Correction to Release Note for Brouter version 2.0
Date:  5/3/91

Copyright 3Com Corporation, 1991.  All rights reserved.

The "Software Release SW/NB-BRR Version 2.0" release notes contain an error
in the upgrade instructions on page 3.  Step 4 tells you to issue the "fl
10030000 25000 0" command.  This is incorrect.  The correct command is "fl
1003000 25000 0".

Likewise, step 5 instructs you to issue the "w 500 10030000 25000" command.
The correct command is "w 500 1003000 25000".

Steps 8 and 10 in the upgrade instructions are correct.

If you use the incorrect commands, your brouter will reboot after the
command in step 4 is issued.