Following are the parameters and abbreviations for the 3+Open DOS
Basic and Enhanced redirectors.  If the switch is marked with a "*" in
the "B" column, the switch is supported on the Basic redirector but only
by its abbreviation.  Thus, /NUMRESOURCES is not valid for the Basic
redirector, but /L is.  If there is no asterisk in the "B" column, the
switch is only supported on the Enhanced redirector.

Switch name        Abbreviation    B    Meaning
-----------        ------------    -    -------
/CHARCOUNT             /CC              Size of pipe buffers
/CHARWAIT              /CW              Default flush timeout for pipe buffers
/CHARTIME              /CT              Default time to wait for pipe data
/COMPUTERNAME          /N               Computer name
/HIMEM                 None        *    Load the redirector into the HMA area
                                        of XMS
/KEEPAPIS              /API             Keep API code
/LANROOT               /I               Root location of 3+Open files
/LANGROUP              /LG              The workstation's LAN group
/LOGONSERVER           /LS              The workstation's centralized logon
                                        server
/MAILSLOTS             /MS              Support mailslots
/NUMCHARBUF            /PN              Number of pipe buffers
/NUMRESOURCES          /L          *    Maximum number of network resources to
                                        access
/NUMSERVERS            /S          *    Maximum number of servers to access
/NUMWORKBUF            /B          *    Number of buffers in the redirector
/NUMVIEWBUFFERS        /MR              Number of receive buffers for mailslots
/NUMVIEWEDSERVERS      /VIEW            Number of servers returned
/NUMMAILSLOTS          /MB              Number of mailslots
/OPTIMIZATIONS         /O          *    Set optimization level
/PR1BUFFSIZE           /P1         *    Printer unit 0 buffer size (LPT1)
/PR2BUFFSIZE           /P2         *    Printer unit 1 buffer size (LPT2)
/PR3BUFFSIZE           /P3         *    Printer unit 2 buffer size (LPT3)
/SINGLERCVBUF          /SB         *    Single receive buffer size
/SIZCHARBUF            /PS              Size of pipe buffers
/SIZWORKBUF            /Z          *    Size of workstation buffers

For compatibility with the IBM PC LAN program, the following abbreviations
are also accepted:

 /NBS is the same as /SIZWORKBUF
 /NBS is the same as /NUMWORKBUF

The /NUMSERVERS values must be at least 2 greater than the /NUMRESOURCES
value.