Ref: 13680017
Title: Quick Setup Procedures for Remote NB Brouters and Bridges
Date: 09/28/90

Copyright 3Com Corporation, 1991.  All rights reserved.

This procedure will help you to set up Remote NetBuilder Brouters
and Bridges quickly.  Read the Brouter Commands and Parameters Guide and
Brouter Operation Guide for detailed descriptions of the Brouter.  Read the
Internetwork Bridge Operation Guide for detailed descriptions of the Bridge.

1.  Connect a terminal to the console port of the NetBuilder system.

2.  Power on the terminal and NetBuilder, and wait for the self-test.

If NetBuilder passes self-test and "System Initialized and Running" appears
on the screen, then press Return to get the "NetLogin:" prompt.

3.  Log in as "root" (use lowercase letters), and press Return for the
password.  (There is no password until you assign one.)

4.  When you get a prompt, type "menu" and press Return.  The Main Menu
varies depending on the Brouter and Bridge software.  Set the configuration
parameters as shown below.

Note:  The Bridge software has no routing capabilities, so skip the IP and
XNS routing parameters when configuring a Bridge.

Note:  With only one serial line, skip commands with "*".

5.  Reboot the system after configuring the parameters.


SYS SERVICE MENU
   Set DATE = yy/mm/dd hh:mm
   SetD DaylightSavingTime = 0 or 60
   SetD NetMapTime = 60
   SetD TimeZone = 300 (Eastern) or 360 (Central) or 420 (Mountain)
                   or 480 (Pacific) and so on....

BRIDGE SERVICE MENU
   SetD CONTrol = Bridge (Bridging and Routing) or
                  NoBridge (only routing)

PORT SERVICE MENU
   SetD !2 CONTrol = Disabled
   SetD !3 CONTrol = Enabled
   SetD !4 CONTrol = Enabled (if necessary) -------------------- *
   Add !3 PAths 3,4 (if both lines go to same destination) ----- *

PATH SERVICE MENU
   SetD !2 CONTrol = Disabled
   SetD !3 CONTrol = Enabled
   SetD !4 CONTrol = Enabled (if necessary) -------------------- *
   SetD !3 CONTrol = ItcmCompatible (if the remote end device
                     has an ITCM card in IB/3)
   SetD !4 CONTrol = ItcmCompatible (if the remote end device
                     has an ITCM card in IB/3 - if necessary) -- *
   SetD !3 CONTrol = T1Mode (if the leased line is for T1, and
                     the remote end divice is a NetBuilder)
   SetD !4 CONTrol = T1Mode (if the leased line is for T1, and
                     the remote end divice is a NetBuilder -
                     if necessary) ----------------------------- *
   SetD !3 CONNector = RS232 or V35
   SetD !4 CONNector = RS232 or V35 (if necessary) ------------- *
   SetD !3 BAud = baud rate for the line (ex, 56 for 56k line)
   SetD !4 BAud = baud rate for the line (if necessary) -------- *

[[ IP ROUTING ]]
IP SERVICE MENU
   SetD CONTrol = ROute
   SetD !1 NETaddr = <IP address> [<subnet mask>]
   SetD !3 NETaddr = <IP address> (when two remote routers are
                                   connected by one or more serial
                                   lines, their serial interfaces are
                                   considered to be on the same
                                   network -- see below example)

   BR/3000 -(Port 3) 10.0.0.3 ---//--- 10.0.0.10 (Port 3)- BR/3000
   (Port 1) 128.31.10.5                       128.45.1.12 (Port 1)

   SetD !4 NETaddr = <IP address> (if necessary) --------------- *

ARP SERVICE MENU
   SetD !1 CONTrol = Proxy
   SetD !3 CONTrol = Proxy
   SetD !4 CONTrol = Proxy (if necessary) ---------------------- *

RIPIP SERVICE MENU
   SetD !1 CONTrol = (TAlk, Listen)
   SetD !3 CONTrol = (TAlk, Listen)
   SetD !4 CONTrol = (TAlk, Listen) (if necessary) ------------- *

[[ XNS ROUTING ]]
IDP SERVICE MENU
   SetD CONTrol = Route
   Add !1 NETnumber <XNS NETnumber>
   Add !3 NETnumber <XNS NETnumber> (when two remote routers are
                                     connected by one or more serial
                                     lines, their serial interfaces
                                     are considered to be on the same
                                     network -- see below example)

   BR/3000 -(Port 3) &00000010 ---//--- &00000010 (Port 3)- BR/3000
   (Port 1) &00034567                            (Port 1) &0003A576

   Add !4 NETnumber <XNS NETnumber> (if necessary) ------------- *

RIPXNS SERVICE MENU
   SetD CONTrol = (Enable, Trigger)