Ref: 11640004
Title: How to Set and Test EtherLink Cards
Date: 8/15/88

Copyright 3Com Corporation, 1991.  All rights reserved.

The following pages show the configurations of the 3C501 and the
3C505 EtherLink cards.  When you have set the EtherLink cards,
test the configuration and cables.

The EtherLink II card has menu-driven diagnostics and is self
explanatory.  Setting up the base I/O on an EtherLink II card is
also self explanatory; find the jumpers (shunts) on the card and
move the jumper to the desired setting.


Echo Server Test

Use the Echo Server Test for testing network cables such as thin
Ethernet, because it is less forgiving of cable problems than
normal usage with 3Plus.  It is especially useful when the tester
does not have an ohm meter or is unsure of the cable
specifications and layout.

You will need to set up a workstation with an EtherLink card as an
echo server, to echo test packets transmitted by the testing
server.  (Note:  Setting up a 3c505 as an echo server and running
the test from a 3c501 will give false-positive results for cabling
errors.)

After the echo server is set up, run the diagnostics from the
testing server and check the results.  If it passes, the cables
are fine.  If it doesn't, you probably have general cable
problems.  Check your card settings against the following lists.


                    STANDARD ETHERLINK CARD
                              3C501

1: BASE I/O of 300               Shunts #4,5,6,7 are off.
2: ECHO SERVER                   3C501 7
3: DIAGNOSTICS TO ECHO SERVER    3C501
4: LOOPBACK TEST                 3C501 L


1: BASE I/O of 310               Move shunt #4 on; #5,6,7 off.
2: ECHO SERVER                   3C501 I3 D1 B310 7
3: DIAGNOSTICS TO ECHO SERVER    3C501 I3 D1 B310
4: LOOPBACK TEST                 3C501 I3 D1 B310 L


1: BASE I/O of 320               Move shunt #5 on; #4,6,7 off.
2: ECHO SERVER                   3C501 I3 D1 B320 7
3: DIAGNOSTICS TO ECHO SERVER    3C501 I3 D1 B320
4: LOOPBACK TEST                 3C501 I3 D1 B320 L

1: BASE I/O of 330               Move shunt #4,5 on; #6,7 off.
2: ECHO SERVER                   3C501 I3 D1 B330 7
3: DIAGNOSTICS TO ECHO SERVER    3C501 I3 D1 B330
4: LOOPBACK TEST                 3C501 I3 D1 B330 L

1: BASE I/O of 340               Move shunt #6 on; 4,5,7 off.
2: ECHO SERVER                   3C501 I3 D1 B340 7
3: DIAGNOSTICS TO ECHO SERVER    3C501 I3 D1 B340
4: LOOPBACK TEST                 3C501 I3 D1 B340 L

1: BASE I/O of 350               Move shunt #4,6 on; #5,7 off.
2: ECHO SERVER                   3C501 I3 D1 B350 7
3: DIAGNOSTICS TO ECHO SERVER    3C501 I3 D1 B350
4: LOOPBACK TEST                 3C501 I3 D1 B350 L

1: BASE I/O of 360               Move shunt #5,6 on; #4,7 off.
2: ECHO SERVER                   3C501 I3 D1 B360 7
3: DIAGNOSTICS TO ECHO SERVER    3C501 I3 D1 B360
4: LOOPBACK TEST                 3C501 I3 D1 B360 L

1: BASE I/O of 370               Move shunt #4,5,6 on 7 off.
2: ECHO SERVER                   3C501 I3 D1 B370 7
3: DIAGNOSTICS TO ECHO SERVER    3C501 I3 D1 B370
4: LOOPBACK TEST                 3C501 I3 D1 B370 L

1: BASE I/O of 380               Move shunt #7 on; #4,5,6 off.
2: ECHO SERVER                   3C501 I3 D1 B380 7
3: DIAGNOSTICS TO ECHO SERVER    3C501 I3 D1 B380
4: LOOPBACK TEST                 3C501 I3 D1 B380 L

1: BASE I/O of 390               Move shunt #4,7 on; #5,6 off.
2: ECHO SERVER                   3C501 I3 D1 B390 7
3: DIAGNOSTICS TO ECHO SERVER    3C501 I3 D1 B390
4: LOOPBACK TEST                 3C501 I3 D1 B390 L

                    ETHERLINK PLUS CARD
                              3C505


1: BASE I/O of 300               Shunts #4,5,6,7 are off.
2: ECHO SERVER                   3C505 -7
3: DIAGNOSTICS TO ECHO SERVER    3C505
4: LOOPBACK TEST                 3C505 L

1: BASE I/O of 310               Move shunt #4 on; #5,6,7 off.
2: ECHO SERVER                   3C505 -I3 -D1 -B310 -7
3: DIAGNOSTICS TO ECHO SERVER    3C505 -I3 -D1 -B310
4: LOOPBACK TEST                 3C505 -I3 -D1 -B310 L

1: BASE I/O of 320               Move shunt #5 on; #4,6,7 off.
2: ECHO SERVER                   3C505 -I3 -D1 -B320 -7
3: DIAGNOSTICS TO ECHO SERVER    3C505 -I3 -D1 -B320
4: LOOPBACK TEST                 3C505 -I3 -D1 -B320 L

1: BASE I/O of 330               Move shunt #4,5 on; #6,7 off.
2: ECHO SERVER                   3C505 -I3 -D1 -B330 -7
3: DIAGNOSTICS TO ECHO SERVER    3C505 -I3 -D1 -B330
4: LOOPBACK TEST                 3C505 -I3 -D1 -B330 L

1: BASE I/O of 340               Move shunt #6 on; #4,5,7 off.
2: ECHO SERVER                   3C505 -I3 -D1 -B340 -7
3: DIAGNOSTICS TO ECHO SERVER    3C505 -I3 -D1 -B340
4: LOOPBACK TEST                 3C505 -I3 -D1 -B340 L

1: BASE I/O of 350               Move shunt #4,6 on; #5,7 off.
2: ECHO SERVER                   3C505 -I3 -D1 -B350 -7
3: DIAGNOSTICS TO ECHO SERVER    3C505 -I3 -D1 -B350
4: LOOPBACK TEST                 3C505 -I3 -D1 -B350 L

1: BASE I/O of 360               Move shunt #5,6 on; #4,7 off.
2: ECHO SERVER                   3C505 -I3 -D1 -B360 -7
3: DIAGNOSTICS TO ECHO SERVER    3C505 -I3 -D1 -B360
4: LOOPBACK TEST                 3C505 -I3 -D1 -B360 L

1: BASE I/O of 370               Move shunt #4,5,6 on; #7 off.
2: ECHO SERVER                   3C505 -I3 -D1 -B370 -7
3: DIAGNOSTICS TO ECHO SERVER    3C505 -I3 -D1 -B370
4: LOOPBACK TEST                 3C505 -I3 -D1 -B370 L

1: BASE I/O of 380               Move shunt #7 on; #4,5,6 off.
2: ECHO SERVER                   3C505 -I3 -D1 -B380 -7
3: DIAGNOSTICS TO ECHO SERVER    3C505 -I3 -D1 -B380
4: LOOPBACK TEST                 3C505 -I3 -D1 -B380 L

1: BASE I/O of 390               Move shunt #4,7 on; #5,6 off.
2: ECHO SERVER                   3C505 -I3 -D1 -B390 -7
3: DIAGNOSTICS TO ECHO SERVER    3C505 -I3 -D1 -B390
4: LOOPBACK TEST                 3C505 -I3 -D1 -B390 L