Ref: 11420018
Title: Possible Cause and Fix for "Eth Trap 3306" Error
date: 4/13/90

Copyright 3Com Corporation, 1991.  All rights reserved.

A 3Server3 was powered off one night due to an unknown cause.  In the
morning after powering on, the LCD displayed the message "Eth Trap 3306."
The same message continued to appear after the server was reset or was
powered off and powered on again.

The problem may have been caused by corrupt 586 Ethernet controller frame
descriptors.  If this is the problem, the 3Server 3 will come up again after
you establish a console connection and copy the ETH3.SYS driver back onto
the server.