Ref: 10860026
Title: Address 000000 after TokenBoot on 3Server or 3Server3
Date: 7/28/88

Copyright 3Com Corporation, 1991.  All rights reserved.

Address 000000: The conditions that will cause this message to
appear during TokenBoot on a 3Server or a 3Server3:

1.  3Server:  This message means the 3Server was unable to
communicate with the adapter.  The possible causes are

a.   Bad or loose ribbon cable to TokenConnection;
b.  Bad or loose power cable to TokenConnection;
c. Bad TokenConnection board.

2.  3Server3:  This message means the 3Server was unable to
commnunicate with the adapter.  The possible causes are:

a, b, or c.  Same as above.
d.  The W009 jumper on the CMEII board was not removed and
the ROM tests were bypassed using the strobe switch.
(The W009 jumper disables the serial port on the
CMEII board, thus preventing conflict with the one on
the TokenConnection board.)