Ref: 10710086
Title: Using an EtherLink plus in a WYSE 286
Date:  7/20/88

Copyright 3Com Corporation, 1991.  All rights reserved.

The 3Com EtherLink Plus card and LPO work fine in the WYSE 286
machines in either the 8 bit slot or the 16 bit slot.  If the
card is put into the 16 bit slot, then interupt 9, DMA 5 and
address 300H work:

eth505.sys 9 300 5

All possible DMAs and interrupts were tried; this was the only setting
that worked.  If there is a problem using WYSE's Vman (their above
memory), the DMA and interrupt have not been set right.  All problems
went away when this setting was used.