Ref: 10630004
Title: Custom PAD Profiles for GS/X.25-IP Connection Service
date: 3/7/90

Copyright 3Com Corporation, 1991.  All rights reserved.

A custom PAD profile can be defined and assigned on a per-port
basis for use when issuing CALL REQUESTS to the GS/X.25-IP from
a PAD.  In an automatic connection service, the profile is used
during data transfer and is issued to the PAD by the GS/X.25-IP
upon receipt of the Telnet connection confirmation and following
the X.25 CALL ACCEPT response from the GS/X.25-IP to the PAD.  An
extended connection service will issue the profile when entering
command mode.

There are two default PAD profiles: a transparent profile
and a regular profile.  These two profiles can be used as
skeletons to create custom profiles.  The two profiles selected
are CCITT simple standard profile # 90 and CCITT transparent
standard profile # 91.

The maximum number of custom profiles is 32.  To create a custom
profile using the skeletons, it is necessary to ReaD the desired
profile into the assigned profile number:

    ReaD PROFile <destination profile> [= <source profile> ]

The range of "source profile" values is 1-32, 90, and 91.
If no source profile is defined, the default profile is 90.
The "destination profile" range is 1-32.

If the desired skeleton to be used is profile # 90 and it is to
be defined as profile number 5, either of the following commands
could be executed:

    ReaD PROFile 5
          or
    ReaD PROFile 5 = 90

To modify any of the 22 possible X.3 parameters, execute the following
Set PROFile command:

    Set PROFile <profile number> [<X.3 parameter>  = <value>],...

To show a profile's current parameter setting, execute the
following SHow command:

    SHow PROFile <profile number> [<X.3 parameter number>],...

To save the custom profile configuration, execute the following
SAve command:

    SAve PROFile <profile number>

To remove the profile definition, execute the following UNSave
command:

    UNSave PROFile <profile number>

To show profiles currently defined, execute the following SHow
command:

    SHow PROFile ALL

The profile must be assigned to the desired port number via the
command:

    Setd Port <port number> PROFile={<profile number> | NONE }

The specification of "NONE" will remove the profile assignment
for the specified port.

The current profile-to-port assignment can be displayed via the
following SHow command:

SHow Port [<port number>] PROfile


DEFAULT PAD PROFILES

CCITT Simple Standard PAD Profile # 90:

Parameter       Name                    Value

    1       Escape from data transfer       1
    2       ECHOData                        1
    3       DataForward                     126
    4       IdleTimer                       0
    5       FlowCtlFrom                     1
    6       InterAction                     1
    7       BreakAction                     2
    8       DataDelivery                    0
    9       CarriageReturnPadding           0
    10      Line Folding                    0
    11      DTE-C Speed                     not configurable
    12      FlowCtlTo                       1
    13      LFInsertion                     0
    14      Line Feed Padding               0
    15      Local Editing                   0
    16      ERAse                           127
    17      LineERAse                       24
    18      ReprintLine                     18
    19      EditPADServiceSignals           1
    20      ECHOMask                        0
    21      ParityTreatment                 0
    22      PageWait                        0



CCITT Transparent Standard PAD Profile # 91:

Parameter       Name                    Value

    1       Escape from data transfer       0
    2       ECHOData                        0
    3       DataForward                     0
    4       IdleTimer                       20
    5       FlowCtlFrom                     0
    6       InterAction                     0
    7       BreakAction                     2
    8       DataDelivery                    0
    9       CarriageReturnPadding           0
    10      Line Folding                    0
    11      DTE-C Speed                     not configurable
    12      FlowCtlTo                       0
    13      LFInsertion                     0
    14      Line Feed Padding               0
    15      Local Editing                   0
    16      ERAse                           127
    17      LineERAse                       24
    18      ReprintLine                     18
    19      EditPADServiceSignals           1
    20      ECHOMask                        0
    21      ParityTreatment                 0
    22      PageWait                        0