Ref: 09580006
Title: Configuring 3Servers to Add a Tape Drive
Date: 2/1/91

Copyright 3Com Corporation, 1991.  All rights reserved.

If you add a tape drive to a 3Server, 3Server70, 3Server3, or 3S/200 server,
you must reconfigure the tape drive; otherwise, the hard disk drive will
fail.  Make sure that these conditions are met:

1.  The tape drive must be configured for SCSI address 7.

2.  The tape drive must be terminated on the SCSI bus.

    * WANGTEK tape drive termination should be done on the
      controller (P/N 1742-01).  Requires three resistor packs.

    * TANDBERG or ARCHIVE tape drive termination should be done on
      the tape drive.  Requires three resistor packs.

3.  The parity jumper on ARCHIVE/TANDBERG drives must be removed.  (The
Wangtek tape controller comes with the parity jumper removed.)