Ref: 04400021
Title: 3+Start and older Incompatible versions on 3S
Date: 7-21-88

Copyright 3Com Corporation, 1991.  All rights reserved.

When executing "3s dir vol_name /link", to get the addresses of
machines that were linked to "vol_name", got the error message
"invalid count number".

The problem was that the new 3S (1.3) was running against an old
Start server.  The old software had lower limits on the number of
users and the number of users linked to a volume, etc.  3S tells
the start server how many users it can handle responses for, and
3S was telling the Start server it could handle more than the
Start server was willing to allow.

This problem will appear as customers migrate to the new version
and fail to upgrade all copies.