Ref: 02880071
Title: Using TokenLink and New G-10 ROMs
Date:  08/08/88

Copyright 3Com Corporation, 1991.  All rights reserved.

There are 2 3+ drivers on the TokenLink diskette.
.br;1) tokodd.sys for 1.0 and 1.1 networks
.br;2) tok603.sys for 1.2 networks

These drivers are specified for these networks due to the
software, not having anything to do with the 3S CME ROMs.  Use
ALL 1.1 drivers on all Token Ring adapters (TL, TL+, IBM, Token
Connection), or ALL 1.2 drivers.  The different driver levels
CANNOT be INTERMIXED on the network.

The tokodd.sys driver originally shipped with the TokenLink would
not establish a 3Console with a 3Server3.  Other boards could be
used (TokenLink+, IBM), but TokenLink did not work.  That problem
was fixed and 3COM shipped a current version of Tokodd.sys.
Upgrade diskettes were shipped to everyone who had ordered
TokenLinks already.

ROMS

All of this ROM info ONLY affects establishing a 3Console with a
3Server from a TokenLink workstation.
There will not be a problem when using a PC server, if you load
the software using an IBM or a Tokenlink Plus when adding
Tokenlinks to an existing network.

3Servers shipped from the factory prior to 9/87 had G8 ROMs.
Establishing a 3console to a 3Server3 with G8 ROMs using a
TokenLink, will require you to use the 1.1 driver on the
TokenLink-tokodd.sys.  (7/87)